Sewage Composite Carbon Source
Character: Clear near water-white liquid
Usage: Water treatment
Package: 1000L IBC tank or Flexibag.
Storage: It should be stored in a dry and ventilative warehouse, kept away from heat and moisture during transportation, unloaded with care so as to avoid damage. Furthermore, it must be stored separately from poisonous substances.
- Product Description
Sewage Composite Carbon Source – Advanced Biological Nutrient Removal Solution
Shanxi Zhaoyi Chemical Co., Ltd. brings 36 years of acetate manufacturing expertise to wastewater treatment with our premium Sewage Composite Carbon Source. This clear, near water-white liquid delivers exceptional COD performance ranging from 15.6×10⁴ to 110×10⁴ mg/L, specifically engineered for industrial and municipal biological denitrification processes.
Our formulation improves total nitrogen removal rates from 60% to over 85%, ensuring Class A discharge compliance (≤15 mg/L TN). With a microbial utilization rate of BOD₅ equivalent ≥0.8, you'll reduce carbon source dosage by 10-20% compared to traditional alternatives. Backed by our 150,000-ton annual production capacity and ISO, KOSHER, and HALAL certifications, this non-flammable solution simplifies safety protocols while optimizing your wastewater treatment efficiency.
Key Features & Benefits
Superior Denitrification Performance
Our product ensures stable total nitrogen removal exceeding 85% efficiency. You'll meet stringent Class A standards (TN ≤15 mg/L) even with fluctuating influent loads.
Cost-Effective Operation
Save 20-40% per unit of nitrogen removed compared to sodium acetate. The high BOD₅/COD ratio (≥0.8) means more effective carbon per dollar spent.
Versatile Application Range
Works efficiently across 5°C to 35°C, with specialized anti-freeze formulation. Your operations won't slow down during winter months like traditional carbon sources.
Enhanced Safety Profile
Non-flammable and non-explosive classification eliminates explosion-proof storage requirements. You'll reduce insurance premiums and simplify compliance documentation.
Minimal Sludge Impact
Completely biodegradable with no refractory intermediates. Your sludge volume stays manageable, reducing disposal costs by preventing filamentous bulking.
Technical Specifications
Parameter | Specification |
Appearance | Clear near water-white liquid |
CODcr Range | 15.6×10⁴ – 110×10⁴ mg/L |
BOD₅/COD Ratio | ≥0.8 |
Total Nitrogen Content | <0.05% |
Total Phosphorus Content | <0.01% |
pH Value | 6.0 – 8.0 |
Density (20°C) | 1.10 – 1.25 g/cm³ |
Operating Temperature | 5°C – 35°C |
Heavy Metals (As, Pb, Cd, Cr) | <10 ppm (total) |
Shelf Life | 12 months (proper storage) |
How It Works?
Step 1: Microbial Activation
When dosed into anoxic tanks, the Sewage Composite Carbon Source immediately becomes available to heterotrophic denitrifying bacteria. Its multi-chain carbon structure provides both rapid-release and sustained-release energy sources.
Step 2: Nitrate Reduction
Denitrifiers consume nitrate (NO₃⁻) and nitrite (NO₂⁻) as terminal electron acceptors. Your system converts nitrogen compounds into harmless N₂ gas that escapes naturally.
Step 3: Metabolic Optimization
The composite formulation includes metabolic boosters that maintain cell membrane fluidity. This ensures efficient enzyme activity even at low temperatures where traditional sources fail.
Step 4: Complete Mineralization
Unlike refractory organics, our product degrades completely to CO₂ and H₂O. You won't accumulate stubborn intermediate compounds that complicate downstream treatment.
Our Factory
30-YEAR ACETATE SPECIALIST | Non-caking, High Purity, Global Supply Chain



Applications
Metropolitan Wastewater Treatment Plant Upgrades
Upgrading from Lesson I B to Lesson I A measures? Our item compensates for influent carbon changes when dosed into anoxic tanks or post-denitrification channels. You'll accomplish steady TN expulsion without enormous framework expansion.
Industrial Wastewater with Tall Nitrate Load
Chemical, pharmaceutical, and electroplating offices confront tall nitrogen with inadequately organics. The composite source gives fundamental promptly biodegradable COD (rbCOD) to support denitrifiers in toxicity-stressed environments.
Low-Temperature Operations
Northern climates or winter seasons moderate microbial energy significantly. Our detailing keeps up >85% productivity in water temperatures as moo as 5-8°C where sodium acetic acid derivation crystallizes.
Membrane Bioreactor (MBR) Systems
Precision dosing in compact MBR setups requires dependable carbon quality. Your framework benefits from reliable COD values and insignificant particulates that seem foul films.






Sewage Composite Carbon Source vs Other Products
Feature | Sewage Composite Carbon Source | Sodium Acetate | Methanol | Glucose |
Cost Efficiency | High (20-40% savings) | Moderate | Low | Moderate |
Safety Classification | Non-hazardous | Non-hazardous | Flammable (Class 3) | Non-hazardous |
Low-Temp Performance (5-8°C) | Excellent (>85% efficiency) | Poor (crystallizes) | Moderate | Poor |
Sludge Bulking Risk | Minimal | Minimal | Low | High |
Biodegradability | Complete (BOD₅/COD ≥0.8) | Complete | Complete | Partial |
Storage Requirements | Standard tanks | Standard tanks | Explosion-proof | Standard tanks |
Secondary Pollution | None (low N, P) | None | None | Potential (high sludge) |
Certifications & Compliance
Our manufacturing facility and products have passed rigorous international quality standards:
· ISO 9001:2015 – Quality Management System certification ensuring consistent product excellence
· KOSHER Certification – Approved production processes meeting strict dietary compliance
· HALAL Certification – Certified ingredients and manufacturing protocols
We conduct routine third-party testing for heavy metals, biodegradability, and COD accuracy. Every batch comes with a Certificate of Analysis (COA) documenting specification compliance.






Packaging Options
1000L IBC Tanks
Industry-standard intermediate bulk containers with bottom discharge valves. Ideal for automated dosing systems with minimal handling requirements.
Flexibag (20,000L)
Cost-effective bulk transport in standard 20-foot containers. Perfect for large-scale operations requiring frequent deliveries.
Custom Packaging Available
Contact us at sxzy@sxzhaoyi.com for specialized packaging solutions tailored to your facility's requirements.
Packing

Manufacturing Process
Crude Fabric Selection
We source high-purity acetic acid derivation forerunners from our coordinates generation lines. Our 36-year supply chain guarantees reliable quality and availability.
Controlled Blending
Multi-stage mixing combines different carbon chain lengths for ideal biodegradability. Exactness dosing of metabolic enhancers happens in temperature-controlled reactors.
Quality Verification
In-line COD analyzers screen each generation bunch. Overwhelming metal screening and biodegradability testing happen some time recently bundling approval.
Contamination Prevention
Closed-loop exchange frameworks anticipate particulate presentation. Nitrogen covering secures delicate compounds from oxidative corruption amid capacity.
Shipment



Why Choose Us?
Decades of Chemical Fabricating Excellence
Since 1988, we've created over 5 million tons of acetic acid derivation items. Your supply chain benefits from our demonstrated unwavering quality and specialized expertise.
Massive Generation Capacity
Our 150,000-ton yearly capacity over a 27,000 m² office guarantees you'll never confront supply disturbances. We keep up vital stock for just-in-time delivery.
Global Quality Standards
Exported to Europe, America, and Asia with full administrative compliance. Our items meet the strictest worldwide wastewater treatment requirements.
Technical Bolster Team
Our engineers help with dose calculations and framework optimization. You'll get personalized direction based on your particular influent characteristics.
Customer-Centric Philosophy
We prioritize long-term associations over value-based deals. Your operational victory drives our persistent item change activities.
FAQ
Q: How does measurement calculation work for the product?
A: Utilize this equation: Measurement = (Target TN Evacuation × C/N Proportion) / (Item COD esteem). The C/N proportion regularly ranges from 4:1 to 6:1 depending on broken down oxygen levels and inner recirculation.
Q: Will exchanging cause slime bulking issues?
A: No. Not at all like glucose or methanol which trigger filamentous microbes development when overdosed, our definition favors floc-forming microscopic organisms. Your slime settling properties (SVI) stay stable.
Q: What around combustibility dangers like methanol?
A: Our item is classified as non-hazardous and non-flammable. You'll kill explosion-proof capacity offices and streamline fire security compliance dramatically.
Q: How does execution compare in winter conditions?
A: The composite detailing incorporates alcohols and organic promoters that keep up bacterial layer smoothness. You'll see >85% effectiveness kept up indeed underneath 10°C.
Q: Can this anticipate auxiliary contamination from the carbon source itself?
A: Yes. With TN <0.05% and TP <0.01%, our product adds negligible nutrients. You won't create new pollution while solving nitrogen removal challenges.
Request a Quote
Ready to optimize your wastewater treatment costs while improving compliance with Sewage Composite Carbon Source? Contact our technical sales team today for customized pricing and application support: sxzy@sxzhaoyi.com
YOU MAY LIKE
VIEW MOREOilfield Liquid Potassium Formate
VIEW MOREOrganic Agricultural Solid Potassium Formate
VIEW MOREAgricultural Liquid Potassium Acetate
VIEW MORESnow Melting Solid Potassium Acetate
VIEW MOREPharmaceutical Excipient Sodium Acetate Anhydrous
VIEW MOREAntibiotic Sodium Acetate Trihydrate
VIEW MORESewage Sodium Acetate Anhydrous
VIEW MOREDrilling Solid Potassium Formate



